product name Popular Design Fingertip Pulse Oximeter
Major Features
Small in volume\light in weight and convenient in carrying
Operation of the product is simple ,low power consumption
Operation menu for the function setting
SpO2 value display
Pulse rate value display, bar graph display
Pulse waveform display
PI Display
Screen brightness can be changed
A pulse rate sound indication
With measured data overruns limits and low-voltage alarm function,the upper/down alarm range can be adjustable
Battery capacity indication
Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage ,and with alarm function
With clock function
Review function
With data record function of multiuser, continuous record about 24 hours data for each user, and the record data can be uploaded to computer
Touch key operation and locking touch key function
It can be connected with adult,child,infant oximeter probe
Wireless communication function(CMS60FW)
Instructions
Principle of the CMS60F Pulse Oximeter is as follows: Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning & Recording Technology,the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger.The product is suitable for being used in family, hospital, oxygen bar, community healthcare, physical care in sports (It can be used before or after doing sports, and it is not recommended to use the device during the process of having sport) and etc.
Main performance
Display Mode:2.8" TFT Color display
Screen Resolution:320*240
SpO2 Measuring Range:0%~100%, (the resolution is 1%).
Accuracy:70%~100%:±2% ,Below 70% unspecified.
PR Measuring Range:30bpm~250bpm, (the resolution is 1bpm)
Accuracy:±2bpm or ±2% (select larger)
Measurement Performance in Weak Filling Condition:SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
Voltage:DC 3.6V~4.2V
Power Supply:Voltage 3.7 rechargeable lithium battery × 1
Battery working hour: 8 hours
Battery working life:Charge and discharge no less than 500 times.
Safety Type:Interior Battery,BF Type
Accessories
Sell in standard
a user manual
A power adapter(GTM41076-0605;CMS0105)
a data line
a disk (PC software)
An oximeter probe
Sell in addition
Other Oximeter Probe (Refer to probe application instruction for details and notice renewal)
Physical Identity
Dimension:94.25(L) × 55.32(W) × 9.6(H) mm
Weight:About 80g (with a lithium battery)